TSR 0.6-48240WI

TSR 0.6-48240WI

  • 厂商:

    TRACOPOWER

  • 封装:

    SIP3 模块

  • 描述:

    非隔离 PoL 模块 直流转换器 1 输出 24V 400mA 33V - 72V 输入

  • 数据手册
  • 价格&库存
TSR 0.6-48240WI 数据手册
Non-Isolated DC/DC Converter (POL) • Ultra wide 8:1 input voltage range: 9-72 VDC • Covers a majority of standard bus- and battery voltages • Up to 94% efficiency - No heatsink required • Pin compatible with LMxx linear regulators (SIP-3) • Operating temperature range -40 to +85°C • • • Low standby current • 3-year product warranty Excellent line/load regulation Protection against short circuit, overvoltage and overtemperature TSR 0.6WI Series, 0.6 A The TSR 0.6WI is a non-isolated POL converter series with an ultra wide 8:1 input voltage range which comes in a standard SIP-3 package. Covering the majority of standard bus- and battery voltages this POL converter is a versatile solution for many applications in distributed power systems where different input voltages have to be handled. Being able to use the same converter in many different situations effectively reduces the bill of material (BOM) of a given application. A high efficiency of up to 94% allows for an operating temperature range of -40 to +85°C (up to 80°C without derating) and makes them excellent drop-in replacements for less efficient LMxx linear regulators. With 0.6A max. output current and standard features such as low standby current, precise regulation and protection against short circuit, overvoltage and overload the TSR 0.6WI is suitable for many battery and distributed power applications. Models Order Code Output Current max. Input Voltage Range TSR 0.6-4833WI 9 - 72 VDC (48 VDC nom.) TSR 0.6-4850WI TSR 0.6-4865WI 600 mA Output Voltage nom. Efficiency typ. 3.3 VDC 85 % (at 24 Vin) 5 VDC 89 % (at 24 Vin) 6.5 VDC 91 % (at 24 Vin) TSR 0.6-4890WI 14 - 72 VDC (48 VDC nom.) 9 VDC 92 % (at 24 Vin) TSR 0.6-48120WI 17 - 72 VDC (48 VDC nom.) 12 VDC 93 % (at 24 Vin) TSR 0.6-48150WI 20 - 72 VDC (48 VDC nom.) 15 VDC 94 % (at 24 Vin) 33 - 72 VDC (48 VDC nom.) 24 VDC 94 % (at 48 Vin) TSR 0.6-48240WI 400 mA Options on demand (backorder with MOQ - Optional models for horizontal mounting (see outline dimensions) non stocking item) Note - It is recommended to use an external input filter, please refer to application note: www.tracopower.com/overview/tsr0-6wi www.tracopower.com September 21, 2022 Page 1 / 5 TSR 0.6WI Series, 0.6 A Input Specifications Input Current - At no load Recommended Input Fuse 3 mA typ. 800 mA (slow blow) 800 mA (slow blow) 1'000 mA (slow blow) 1'000 mA (slow blow) 1'000 mA (slow blow) 1'000 mA (slow blow) 800 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) See application note: www.tracopower.com/overview/tsr0-6wi (Recommended external input filter proposal) 3.3 Vout models: 5 Vout models: 6.5 Vout models: 9 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: Input Filter Output Specifications Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (10 - 100%) Ripple and Noise (20 MHz Bandwidth) 3.3 Vout models: 5 Vout models: 6.5 Vout models: 9 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: Capacitive Load Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Transient Response - Peak Variation - Response Time ±2.5% max. 0.9% max. 0.6% max. 50 mVp-p typ. 50 mVp-p typ. 50 mVp-p typ. 50 mVp-p typ. 50 mVp-p typ. 50 mVp-p typ. 75 mVp-p typ. 100 µF max. Not required ±0.02 %/K max. 50 ms typ. (24 Vout model) 25 ms typ. (other models) Continuous, Automatic recovery 200% typ. of Iout max. 90 mV typ. / 180 mV max. (50% Load Step) 150 µs typ. / 250 µs max. (50% Load Step) General Specifications Relative Humidity Temperature Ranges Power Derating Over Temperature Protection Switch Off - Operating Temperature - Case Temperature - Storage Temperature - High Temperature - Protection Mode - Measurement Point Cooling System Switching Frequency Insulation System Reliability Washing Process - Calculated MTBF 95% max. (non condensing) –40°C to +85°C +105°C max. –55°C to +125°C See application note: www.tracopower.com/overview/tsr0-6wi 165°C typ. (Automatic recovery) Internal IC temperature Natural convection (20 LFM) 117 - 243 kHz (PWM) (3.3 Vout model) 130 - 270 kHz (PWM) (5 Vout model) 163 - 338 kHz (PWM) (6.5 Vout model) 195 - 405 kHz (PWM) (9 Vout model) 247 - 513 kHz (PWM) (12 Vout model) 293 - 608 kHz (PWM) (15 Vout model) 416 - 864 kHz (PWM) (24 Vout model) Non-isolated 18'160'000 h (MIL-HDBK-217F, ground benign) Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 21, 2022 Page 2 / 5 TSR 0.6WI Series, 0.6 A Environment MIL-STD-810F MIL-STD-810F MIL-STD-810F Non-conductive Plastic (UL 94 V-0 rated) Epoxy (UL 94 V-0 rated) Brass Nickel (1 - 2 µm) Tin (3 - 5 µm), matte Plastic Case PCB Mount THD (Through-Hole Device) SIP3 Wave Soldering 3g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Vibration - Mechanical Shock - Thermal Shock Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile Weight Environmental Compliance - REACH Declaration - RoHS Declaration Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tsr0-6wi All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 21, 2022 Page 3 / 5 TSR 0.6WI Series, 0.6 A Outline Dimensions Standard: Vertical mounting 0.5 (0.02) 4.1 1 2 Pinout 5.6 (0.22) Function 1 +Vin 2 GND 3 +Vout 0.5 (0.02) 2 x 2.54 (2 x 0.100) 8.6 (0.34) Pin 3 (0.16) 13.4 (0.53) 12.0 (0.47) 3.5 (0.14) Bottom View 0.50 x 0.25 (0.02 x 0.01) Dimensions in mm (inch) Tolerances: x.xx ±0.5 (±0.02) Tolerances: x.xxx ±0.25 (±0.01) Pin dimension tolerances: ±0.10 (±0.04) All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 21, 2022 Page 4 / 5 TSR 0.6WI Series, 0.6 A Optional: Horizontal mounting 0.5 (0.02) 1 2 Pin Function 1 +Vin 2 GND 3 +Vout 3 1.9 (0.08) 13.4 (0.53) Pinout 0.50 x 0.25 (0.02 x 0.01) (0.16) 4.1 (0.08) Bottom View 2.1 8.6 (0.34) 12.0 (0.47) 0.5 (0.02) 2.54 2.54 3.5 0.100) 0.100) (0.14) Dimensions in mm (inch) Tolerances: x.xx ±0.5 (±0.02) Tolerances: x.xxx ±0.25 (±0.01) Pin dimension tolerances: ±0.10 (±0.04) © Copyright 2022 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 21, 2022 Page 5 / 5
TSR 0.6-48240WI 价格&库存

很抱歉,暂时无法提供与“TSR 0.6-48240WI”相匹配的价格&库存,您可以联系我们找货

免费人工找货